Miner normal operating temperature range
Share
To be specific, the temperature of the miner's intake air should fall within this range.
Even if the room temperature is cool, the intake air temperature might still be too high because of the dust accumulation or other reasons. Please clean the miner if needed.
Different models display the miner's temperature differently. Notably, most of our miners have a protection program that puts the miners to shut down at temperature too high.
Below shows the normal temperature of the miners:
Antminer | Temperature in degree Celsius |
S9 series excl. S9i, S9j, S9-Hydro |
Range: 65 - 115 Chip max. 135 PCB max. 90 |
S9i |
PCB max. 85 |
S9j and S9-Hydro |
PCB max. 95 |
T9 series excl. T9+ |
Range: 65 - 115 Chip max. 135 PCB max. 90 |
T9+ |
Chip max. 125 PCB max. 95 |
L3 |
Range: 30 - 85 PCB max. 85 |
L3+ and L3++ |
Range: 30 - 85 PCB max. 90 |
D3 |
Range: 35 - 80 PCB max. 85 |
D5 |
PCB max.85 |
A3 |
Chip max. 115 PCB max. 85 |
X3 |
Chip max. 127 PCB max. 80 |
B3 |
Chip max. 127 PCB max. 80 |
V9 |
Range: 30 - 70 PCB max. 80 |
Z9 Mini |
Chip max. 125 PCB max. 80 |
Z9 |
PCB max. 80 |
E3 |
PCB max. 65 |
DR3/DR5 |
PCB max. 85 |
S15 |
PCB max. 80 |
S11 |
PCB max. 95 |
T15 |
PCB max. 80 |
S17/S17 Pro/T17 |
PCB max. 75 |
S9 SE/S9k |
PCB max. 85 |
S17e/T17e/S17+ |
PCB max. 80 |
T17+ |
PCB max. 75 |
If you notice that the temperatures are climbing and nearing the temperature limit, contact us for assistance and technical advice.